Description

Feature

  1. 12-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
  2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real-time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
  3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
  4. SPO2 can testing for 0.1% Weak;
  5. RA-LL impedance Respiration;
  6. Trend Coexist Display;
  7. OxyCRG DyNamic View Display;
  8. Bed to Bed view Display;
  9. Networking capacity and nurse calling system;
  10. Options of Internal Recorder, IBP, EtCO2, Central Monitoring System
  11. Built-in rechargeable battery 4400mAh;
  12. 12.1″ high resolution color TFT LCD display;
  13. Large volume of tabular and graphic trends information storage and easy to recall;
  14. Anti-ESU, anti- defibrillator;
  15. Capture dynamic waveforms.

Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

Heart Rate and Alarm

Range

-Adult: 15 ~ 300 bpm

-Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great

Resolution: 1 bpm

Sensitivity: >200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: <10uA

Baseline Recovery: < 3S after Defi.

ECG Signal Range: ±8 m V (Vp-p)

Bandwidth

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

Respiration

Method: Impedance between R-F (RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range: 0.3 ~ 5.0Ω

Base line Impedance Range: 0 ~ 2.5 KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range

 Adult Mode

-SYS: 40 ~ 270 mmHg

-DIA: 10 ~ 215 mmHg

-MEAN: 20 ~ 235 mmHg

 Pediatric Mode

-SYS: 40 ~ 200 mmHg

-DIA: 10 ~ 150 mmHg

  -MEAN: 20 ~ 165 mmHg

Neonatal Mode

-SYS: 40 ~ 135 mmHg

-DIA: 10 ~ 100 mmHg

-MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

-Adult Mode: 297±3 mmHg

-Pediatric Mode: 240±3 mmHg

-Neonatal Mode: 147±3 mmHg

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy: ±2bpm

Temperature

Channel: 2

Measuring and Alarm Range: 0 ~ 50°C

Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec.

Average Time Constant:<10 Sec.

IBP(optional)

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

-ART: 0 ~ 300 mmHg

-PA: -6 ~ 120 mmHg

-CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

-P1/P2: -10 ~ 300 mmHg

Press Sensor

Sensitivity: 5uV/V/mmHg

Impedance: 300-3000Ω

Resolution: 1 mmHg

Accuracy: ±2% or ±1mmHg, which great

Actualization interval: about 1 Sec

Standard Packing List

5-lead ECG cable (including RESP)

Adult finger SpO2 sensor

Adult NIBP cuff

NIBP extension tube

TEMP sensor

AC power adaptor

ECG electrodes

Operation instruction

Optional Function

Internal Recorder, IBP, EtCO2, Central Monitoring System

Brands:

Ari

Reviews

There are no reviews yet.

Be the first to review “ARI 800C Multi parameter ICU Patient Monitor, Complete”

General Inquiries

There are no inquiries yet.

Quick Comparison

SettingsARI 800C Multi parameter ICU Patient Monitor, Complete removeBeurer GL 42 Blood Glucose Monitor (Glucometer)+Free Test Strips removeBeurer Lancet Needle-100 Pieces (Tickle Pin ) remove3M ECG Electrodes 50 Pieces /Pack (Disposable Electrodes) removeBeurer FT 90 Infrared Non-Contact Thermometer removeNew Reusable Large Adult Use Blood Pressure Cuff (42cm-54cm) remove
ImagePatient monitorglucometerecg electrode
SKU
Rating
Price

Free!0.00

350.00500.00

60.00

120.00

350.00375.00

120.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

Description


Beurer FT 90 thermometer is a an infrared non-contact clinical thermometer that takes a patient's temperature across his/her forehead.
  • Assurance of quality, high quality, and fantastic value for money.
  • The hose is made up of two tubes. Circumference of the limbs: 42-54 cm.
  • The cuff is made of PU, which is easy to clean and disinfect. Type of cuff: Reusable with bag.
Content

Feature

  1. 12-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
  2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real-time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
  3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
  4. SPO2 can testing for 0.1% Weak;
  5. RA-LL impedance Respiration;
  6. Trend Coexist Display;
  7. OxyCRG DyNamic View Display;
  8. Bed to Bed view Display;
  9. Networking capacity and nurse calling system;
  10. Options of Internal Recorder, IBP, EtCO2, Central Monitoring System
  11. Built-in rechargeable battery 4400mAh;
  12. 12.1" high resolution color TFT LCD display;
  13. Large volume of tabular and graphic trends information storage and easy to recall;
  14. Anti-ESU, anti- defibrillator;
  15. Capture dynamic waveforms.

Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads (R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 ch

Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

Heart Rate and Alarm

Range

-Adult: 15 ~ 300 bpm

-Neo/Ped: 15 ~ 350 bpm

Accuracy: ± 1% or ± 1bpm, which great

Resolution: 1 bpm

Sensitivity: >200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR

-Monitor: > 105 dB

-Operation: > 105 dB

-Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: <10uA

Baseline Recovery: < 3S after Defi.

ECG Signal Range: ±8 m V (Vp-p)

Bandwidth

-Surgery: 1 ~ 15 Hz

-Monitor: 0.5 ~ 35 Hz

-Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p), Accuracy: ±5%

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

Respiration

Method: Impedance between R-F (RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range: 0.3 ~ 5.0Ω

Base line Impedance Range: 0 ~ 2.5 KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

-Adult: 0 ~ 120 rpm

-Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy: ±2 rpm

Apnea Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,

120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range

 Adult Mode

-SYS: 40 ~ 270 mmHg

-DIA: 10 ~ 215 mmHg

-MEAN: 20 ~ 235 mmHg

 Pediatric Mode

-SYS: 40 ~ 200 mmHg

-DIA: 10 ~ 150 mmHg

  -MEAN: 20 ~ 165 mmHg

Neonatal Mode

-SYS: 40 ~ 135 mmHg

-DIA: 10 ~ 100 mmHg

-MEAN: 20 ~ 110 mmHg

Resolution Pressure: 1mmHg

Accuracy Pressure Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

-Adult Mode: 297±3 mmHg

-Pediatric Mode: 240±3 mmHg

-Neonatal Mode: 147±3 mmHg

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy: ±2bpm

Temperature

Channel: 2

Measuring and Alarm Range: 0 ~ 50°C

Resolution: 0.1°C

Accuracy: ±0.1°C

Actualization interval: about 1 Sec.

Average Time Constant:<10 Sec.

IBP(optional)

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

-ART: 0 ~ 300 mmHg

-PA: -6 ~ 120 mmHg

-CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

-P1/P2: -10 ~ 300 mmHg

Press Sensor

Sensitivity: 5uV/V/mmHg

Impedance: 300-3000Ω

Resolution: 1 mmHg

Accuracy: ±2% or ±1mmHg, which great

Actualization interval: about 1 Sec

Standard Packing List

5-lead ECG cable (including RESP)

Adult finger SpO2 sensor

Adult NIBP cuff

NIBP extension tube

TEMP sensor

AC power adaptor

ECG electrodes

Operation instruction

Optional Function

Internal Recorder, IBP, EtCO2, Central Monitoring System

Quality and original Beurer GL 42 Blood Glucose Monitor ( Glucometer ) with 2 Free test strips available today on the Yolie Online Medical Diagnostics Shop. Visit Yolie today for the cheapest Medical Diagnostics product.

PACKAGE
Beurer GL 42 Blood Glucose Monitor ( Glucometer ) comes with:
  • 2 free test strips
  • Lancet
  • Lancet needle
  • Pouch

SPECIFICATIONS: Beurer GL 42 Blood Glucose Monitor (Glucometer)

  • Blood glucose unit of measurement: mg/dL or mmol/L
  • Clinically tested: Yes
  • Suitable for self-testing: Yes
  • Blood volume required: 0,6 microliter
  • Measurement duration: approx. 5 seconds
  • Coding: CodeFee
  • Reading memory spaces: 480 with date, time
  • Average values blood glucose: for 7, 14, 30 or 90 days
  • Blood sample: fresh whole blood (capillary)
  • AST puncturing (e.g. on the arm): possible
  • AST cap: Yes
  • Measurement range: 20-630 (mg/dL), 1,1-35,0 (mmol/L)
  • Automatic switch-off: Yes
  • Large, easy-to-read display: Yes
KEY FEATURES OF BEURER GL 42 GLUCOMETER
  • Coding: CodeFee
  • Clinically tested: Yes
  • Suitable for self-testing: Yes
  • Blood volume required: 0,6 microliter
  • Measurement duration: approx. 5 seconds
  • Blood glucose unit of measurement: mg/dL or mmol/L


Grab the Beurer Lancet which is in stock now at the Yolie Online Medical and Diagnostic Marketplace. Get one at an affordable price now. Sterile lancet needles ,suitable for all Beurer blood glucose monitors.
  • 100 pieces (4 bags of 25 lancets)
  • Medical device, suitable for self-testing
  • Gentle way to obtain samples
  • Resealable bag
  • Needle size 28G
    Product designation Accessories
    EAN 4211125457013
    Item number 45701
     
Purchase the 3M ECG Electrodes 50's Monitoring Tape at a cool price on the Yolie Online Market. Grab yours now at the best price.
  • 3M Monitoring ECG Electrodes are fluid resistant electrodes that come with a dry gel
  • The gel is conductive aggressive for excellent adhesion and clear, reliable tracings
  • The electrodes have lift tabs for easy placement and removal
  • The electrodes are latex free and are easy to handle
  • These electrodes are ideal for general purpose monitoring providing cost savings through standardization
  • The electrodes come in a standard packing of 100 electrodes per box
  • Suggested Applications: - For tread mill test - Intensive Care Unit (ICU) monitors - Critical Care Unit (CCU) monitors
 
Yolie Diagnostic Medical Market presents medical devices buyers with the proven Beurer infrared non-contact thermometer at the best price on the market. Just Ask Yolie for all your Diagnostic needs Measurement without skin contact! The clinical thermometer ( infrared non-contact thermometer) measures body temperature, ambient temperature and surface temperature.
  • Measurement of body, ambient and surface temperature
  • Hygienic and safe measurement without skin contact
  • Measurement in seconds
  • Infrared measurement
  • Temperature alarm: from 38°C
  • Displays measurements in °C and °F
  • Sound control (On/Off)
  • Measuring distance 2 – 3 cm
  • 60 memory spaces (body temperature)
  • Automatic switch-off
  • Optional acoustic signal when the measurement is complete
  • Medical device
  • Easy-to-read, blue illuminated XL display
  • With storage box
Product designation Non-contact thermometer
Automatic switch-off yes
Low battery indicator yes
Date and time yes
Illuminated display yes
Temperature alarm (display) yes
Non-contact measurement yes
Medical device yes
Measurement of the surface/object/liquid temperature yes
Measurement of room temperature yes
Measurement of forehead temperature yes
Protective cap/box for storage yes
Acoustic signal yes
Memory spaces 60
Can be set to °C/°F yes
Product weight approx. 82 g
Product dimensions 188 x 47.6 x 29 mm
CE yes
Warranty in years (You can find more information about the warranty conditions in the manual.) 5
HMV (products covered by German health insurance) number 21.28.01.2106
PZN (German centralised pharmaceutical number) 10228997
EAN 4211125795313
Item number 79531

Memory function 60 memory spaces

Measuring location Temperature is taken on the forehead
Non-contact measurement Hygienic and safe without skin contact
Surface temperature The surface temperature of objects and liquids
Face icons Laughing smiley = everything is OK, sad smiley = 38°C
Room temperature The product displays the room temperature

Temperature display The temperature is shown on the display (°C/°F)

Adult Use 42cm-54cm Arm Circumference Reusable Blood Pressure Cuff Single Tube

There is no NIBP Connector: Please make sure you have the correct NIBP Connector for your cuff.
  • All monitors are compatible with this software. It's suitable for use in hospitals, nursing homes, and at home.
  • Brand New Professional Quality Reusable Blood Pressure Cuff from an independent manufacturer.
  • Assurance of quality, high quality, and fantastic value for money.
  • The hose is made up of two tubes. Circumference of the limbs: 42-54 cm.
  • The cuff is made of PU, which is easy to clean and disinfect. Type of cuff: Reusable with bag.
Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Compare ×
Let's Compare! Continue shopping